Beckett 7505P1530U, GeniSys® 120V Oil Burner Control
Beckett 7505P1530U, GeniSys® 120V Oil Burner Control
Regular price
$163.26 CAD
Regular price
Sale price
$163.26 CAD
Unit price
per
Product Detail
Beckett 7505P1530U, GeniSys® 120V Oil Burner Control
Features & Benefits
- Water Resistant
- Thermostat and boiler control compatible
- Customizable pre-time and post-time
- Three status lights for system monitoring and diagnostics
- Welded relay protection with redundant motor relays
- Limited reset and limited recycle
- Sleek, modern design
- Technician Pump Prime mode
- 5-Year Warranty
- 7505a replaces Honeywell R8184G
- 7505b replaces Honeywell R7184B
- Two communication ports for adding alarm contacts, programming display, and/or future
Electrical Ratings
Inputs
-
- Voltage: 102 to 132 Vac
- Current: 150 mA plus burner motor, igniter, and valve loads
- Frequency: 60 Hz
Outputs
-
-
Motor: 120 Vac, 10 full load amps (FLA*), 60 locked rotor amps
(LRA)- Note – Reduce motor FLA rating by igniter current
- Igniter: 120 Vac, 3 A @ 0.7 PF min
- Solenoid Valve: 120 Vac, 1 A @ 0.7 PF min
- Thermostat Anticipator Current: 0.1 A
- Thermostat Voltage: 24 Vac
-
Motor: 120 Vac, 10 full load amps (FLA*), 60 locked rotor amps
Application Ratings
-
- Oil Burner Input: < 20gph
- Control Programming: UL372 Group 2
Environmental Ratings
-
- Storage & Operating Ambient Temperature: -40°F to +150°F (-40°C to +65°C)
- Moisture: 5 to 95% RH, non-condensing and non-crystallizing
Approvals
-
- Underwriters Laboratory Recognition per UL372 and UL1998,
and CSA C22.2 No. 199
- Underwriters Laboratory Recognition per UL372 and UL1998,